Connecting the CMU to the network
In-band management
If the CMUs have been configured for in-band management mode, proceed as
follows:
Procedure 5-27 Connect to network – in-band management
1
Disconnect the local PC from the CMU management port at each CMU.
2
At each CMU, connect the CMU Data ports to a router port, switch port or
other network equipment in the data network using Ethernet copper or fiber
cable as appropriate.
3
Check that each of the CMUs is reachable from the network management
system by opening the web interface to the management agents, or by
requesting ICMP echo response packets using the Ping application. The
network management system will normally be geographically remote from
the site, so it may be necessary to request that this action is completed by
co-workers at the management centre. Alternatively, it may be possible to
use remote login to the management system.
Check the data network for correct operation across the wireless link. This
4
may be by requesting ICMP echo response packets between hosts in the
connected network segments, or by some more structured use of network
testing tools.
5-112
Chapter 5 Installation
phn-1478_005v000
Apr 2010