Figure 5-20 Cable Loss Plot For A 17 Meter Cable With Odu Connected - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Figure 5-20 Cable loss plot for a 17 meter cable with ODU connected

0
-5
-10
-15
-20
-25
-30
300
Resolution: 517
Std: ---
Date: 11/11/2009
Model: S311D
Cable loss example using a 100 meter cable
This is similar to the above example, except that there is now 100m of cable
between the two LPUs (length 'y' in
x
Figure 5-21
x
Figure 5-22
phn-1478_005v000
Apr 2010
M1: -11.67 dB @ 350.00 MHz
310
320
330
Frequency (300.0 - 400.0 M Hz)
is a plot of cable loss taken before the ODU was connected.
is a plot of cable loss taken after the ODU was connected.
Cable Loss
ODU 17M
M 1
340
350
360
370
CAL:ON(COAX)
Channel: N/A
Time: 04:12:12
Serial #: 00936036
Figure
5-18). It shows similar results:
Testing the installation
380
390
400
CW: ON
Avg.CableLoss: 12.89 dB
5-81