Resetting Ip And Ethernet Configuration To Factory Defaults; Figure 7-4 Recovery Software Upgrade Complete Page - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Figure 7-4 Recovery Software Upgrade complete page

Resetting IP and Ethernet configuration to factory defaults

Perform this task when the CMU is in recovery mode. The purpose of this task is to
reset IP and Ethernet configuration back to factory defaults.
Before starting this task, check that the Recovery Options page is displayed
7-2).
To reset IP and Ethernet configuration parameters, proceed as follows:
Procedure 7-4 Reset IP and Ethernet configuration in recovery mode
Select Reset IP & Ethernet Configuration back to factory defaults. The
1
Reset Configuration dialog is displayed
Select OK. The Recovery Options page is redisplayed with a message
2
indicating that the configuration has been reset.
Select Reboot. The Reboot Confirmation dialog is displayed
3
Select OK. The reboot progress message is displayed. On completion, the
4
CMU restarts.
To restore the IP and Ethernet configuration to meet the operator's
5
requirements, see
NOTE
phn-1478_005v000
Apr 2010
Configuring the IP and Ethernet interfaces
When the CMU is rebooted after selecting the recovery option Reset IP
& Ethernet Configuration back to factory defaults, the IP address
remains at its default setting of 169.254.1.1 and the CMU can only be
accessed via a direct network connection from the PC to the management
port.
(Figure
7-5).
Recovering the CMU
(Figure
(Figure
6-14).
on page
6-18.
7-17