Step-By-Step Instructions; Figure 4-4 G4 Ex Front End Exploded View - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

4.8.1 Step-by-step instructions

1) Collect data from the unit.
2) Back up the configuration files following the instructions listed previously in
3) Verify that the "LL" battery alarm is not being displayed on the G4 EX LCD.
4) Gain access to the rear termination board by loosening the countersunk hex
5) Disconnect the power connector (J16) from the board mounted connector
2104349 rev. AD
Figure 4–4 G4 EX Front End Exploded View
this chapter.
Remove power from the device, or insure the area is known to be
non-hazardous before removing any enclosure cover. For further
information, refer to the certification drawing indicated on the
device's nametag and national and local electrical codes.
socket locking set screw in the rear end cap. Use a 1/16" hex wrench to
perform this task. Upon completion, unscrew the end cap.
(see Figure 4–5).