4) Center the I/O card over the termination board (green phoenix connectors
5) Using the four 6-32 x .625 standoffs removed previously, connect the I/O
6) Reapply power to the unit. Make the local connection using PCCU32 and
7) In the PCCU32 tree-view, select the I/O Interface application. Once
8) Disconnect, and remove power externally from the unit.
9) Perform field wiring following the diagrams in Chapter 3. If the internal
2104349 rev. AD
facing out). Align the four screw holes at each corner. This should allow the
I/O card to interconnect with I/O Expansion connection on the termination
board. Apply gentle pressure to the I/O card in the two areas located on
either side of the connector until the board is seated.
card to the termination board. Do not over tighten.
the MMI cable. Once physically connected, open PCCU32, and move into
Entry mode.
expanded, click on the 6200EX I/O Card sub-menu. If the user is
communicating properly, they will see the setup screens for the daughter
card.
Figure 6–3 I/O Interface screen
PCCU connector is being reinstalled, field wiring must be done prior to
installation.