Solar Panel Installation; Figure 2-13 Lithium Battery - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

2.2.10 Solar panel installation

The solar panel is designed for outdoor mounting on a 2" extension pipe installed
on the upper end of the 6270 OEU 40" mounting pipe (see Figure 2–14). The solar
panel must be mounted within 12 feet of the 6270 enclosure (other lengths
available). For wall mounted enclosures, it can be mounted on the top or the side
of the meter house.
2.2.10.1
-
-
-
-
-
2.2.10.2
-
Page 2–14
Figure 2–13 Lithium battery
Do not connect the solar panel power cable to the charger
regulator that is located in the 6270 enclosure, unless the
main battery pack has been connected. Refer to the Battery
Pack Installation section.
Exercise caution when installing the solar panel so as not to
damage it.
For solar panel installations where the panel is mounted on
the top or to the side of a meter house, please insure that
the panel receives full sun all day. When mounted, the solar
panel will face up from the horizon at a 50° angle and face
in a southern direction.
The 6270 OEU system with battery and solar panel is rated
for Class I, Division 2 locations only or can be installed in
non-hazardous locations.
Materials supplied
One solar panel
Two U-bolts and fastening hardware
Solar panel cable (if not already attached)
Solar panel mounting bracket (if not already attached to the solar panel)
Pipe mounting kit
Materials not supplied
Cable ties
2104349 rev. AD