12.4
Series commissioning
Introduction
Series commissioning means bringing a series of control systems to the same initial state as
regards their data.
You can archive/read in your choice of PLC, NC and HMI data for series commissioning.
Compensation data can be saved at the same time if necessary. The drive data are saved
as binary data which cannot be modified.
Requirement
The password, e.g., with access level 3 (user) is set.
Note
In order to prevent a topology error, Control Unit parameter p9906 (topology comparison
stage of all components) should be set to "Medium" to load Control Unit series
commissioning.
Operating sequences
1. Open the menu to create a series-commissioning file:
2. Create an archive for the series-commissioning file: You can select which data you wish
3. Archive name: The suggested archive name depends on the selected area and can be
4. Create the series-commissioning file by selecting the component to which you wish the
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
Operating range "Services > ETC key ">" > "Series IBN".
to save as the archive contents:
– HMI
– NC with compensation data
– PLC
– Profibus drives
changed if necessary.
file to be output:
– NC-Card
– Archive
Managing user data
12.4 Series commissioning
213