ABB ACSM1 Firmware Manual page 141

Speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

45.09 MOTNOMTEMPRISE
Defines the temperature rise of the motor when the motor is loaded with nominal current. See the
motor manufacturer's recommendations.
The temperature rise value is used by the motor thermal protection model when parameter
MOT TEMP SOURCE
Motor nominal
temperature rise
0...300 °C
45.10 MOT THERM TIME
Defines the thermal time constant for the motor thermal protection model (i.e. time inside which the
temperature has reached 63% of the nominal temperature). See the motor manufacturer's
recommendations.
The motor thermal protection model is used when parameter
ESTIMATED.
Motor
load
100%
Temp.
rise
100%
63%
Motor thermal time
100...10000 s
FW block:
MOT THERM PROT
is set to
(0)
ESTIMATED.
Temperature
Ambient temperature
Motor temperature rise.
FW block:
MOT THERM PROT
t
t
Motor thermal time.
(see above)
t
(see above)
45.02 MOT TEMP SOURCE
Parameters and firmware blocks
141
45.02
is set to
(0)