Relationships and dependencies of the parameters
Table 6- 8
Relationships and dependencies of the parameters
Parameter
Dependency
PROFINET IO
IP mode
Host name
PROFINET IO device name
PROFINET IO
Host name
device name
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
Description
The parameters of the "PROFINET IO" group are only
active when the "PROFINET (FB79)" or
"PROFINET (Ident profile)" IP mode is selected.
Only if IP mode "PROFINET (FB79)" or
"PROFINET (Ident profile)" is selected does the host
name correspond to the "PROFINET IO device name".
Only if IP mode "Manual" is selected does the
"PROFINET IO device name" correspond to the "Host
name".
Note
If the IP mode "PROFINET (FB79)" or "PROFINET
(Ident profile)" is not set, the "Device name" corresponds
to the "Host name".
Settings
6.1 Communication
111