Lighting - Siemens SIMATIC MV500 Operating Manual

Optical identification
Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Application
5.1 Program
5.1.3.4

Lighting

Table 5- 18
Lighting
Parameter
Possible values
Lamp
Internal
External
Product name
Depends on the option
selected under "Lamp"
Operation
Flash
Permanent light
Off
Polarized
On
Off
Main beam lamp
On
Off
Unpolarized
On
Off
Note
Trigger pulses are ignored while image is being acquired
Trigger pulses arriving while the image is being acquired are ignored because the pulses
cannot be processed. In this case, no (further) image acquisition is started. Instead, image
acquisition and processing are continued and an "N_OK" result (Trigger during image
acquisition) is generated immediately upon completion.
36
Default
Description
Internal
Choose the lamp with which you want to work.
Notes
You define which internal and/or external lamp is
connected in the "Lighting" group of the "Options"
menu.
Depends on the
The product name of the selected lamp is dis-
option selected under
played.
"Lamp"
Depends on the
Depending on the lamp used, you can select the
option selected under
desired operating mode in which to operate the
"Lamp"
lamp.
For lamps that support only one of the two modes,
the setting is fixed.
On
This parameter can be enabled when using an
attachment with polarization filter. By activating
this parameter, the polarized LEDs on the top are
switched on.
Use the parameter to reduce reflections on very
shiny surfaces.
On
This parameter must be switched on when using
a main beam lamp. Enabling this parameter
switches on the external LEDs.
Use these parameters to increase the brightness
of the lighting.
On
Turn on this parameter to use an unpolarized
light. By activating this parameter, the unpolarized
LEDs on the bottom are switched on.
Use these parameters to increase the brightness
of the lighting.
If you subsequently change the parameters of
a selected lamp or connect a different lamp:
A program that uses these lamps (internal or
external) is marked as non-executable. You
must save the program again.
Operating Manual, 05/2019, C79000-G8976-C495-02
SIMATIC MV500