Application
5.1 Program
Table 5- 57
Formatting instruc-
tion
%Q0
%Q1
%q1
%Q2
%q2
%Q4
%q4
%Q6
%q6
%Q9
%q9
%Q10
%q10
%q14
%q15
%q16
%q17
%Q19
%q19
%Q20
%q20
%Q21
%q21
%Q22
%q22
%q34
%q35
86
Quality classes: Siemens DPM (5/F)
Description
Overall quality (O__)
Contrast (SC_)
Integer: 0 ... 100
Axial non-uniformity (AN_)
Fixed point: 0.00 ... 1.00
Unused error correction (UEC)
Fixed point: 0.00 ... 1.00
Cell modulation 1/2 (CM1/CM2)
2x integer
2x 0 ... 100
Print growth X/Y (PGX/PGY)
2x integer
2x 0 ... 200
Cell size (CS_)
Fixed point: 0.0 ... 99.9
ECC level (unevaluated)
Integer: 0, 50, 80, 100, 140, 200
Height (unevaluated)
Fixed point: 0.00 ... 9.99
Width (unevaluated)
Fixed point: 0.00 ... 9.99
Angle (unevaluated)
Integer: 0 ... 360
Center offset (CO_)
Integer
0 ... 99.9
Size offset (SO_)
Fixed point: 0.00 ... 99.9
Border match (BM_)
Integer: 0 ... 100
Angle of distortion (AOD)
Fixed point: -45 ... 45
Cell size in mm
Fixed point: 0.01 ... 9.99
Cell size in pixels
Fixed point: 1.0 ... 99.9
Operating Manual, 05/2019, C79000-G8976-C495-02
SIMATIC MV500

Hide quick links: