Settings
6.2 Options
Time basis
In this group, you specify the source for the time stamp of the diagnostics events.
Table 6- 19
Time basis
Parameter
Source
IP address
Monitoring
In this group, you specify whether live images are displayed in processing mode.
Table 6- 20
Monitoring
Parameter
During processing
Persistence (persistent data storage)
In this group, you specify which diagnostic information you want to store permanently on the
EPROM.
Table 6- 21
Persistence
Parameter/
button
Save next error image ☐ / ☑
Save next data rec-
ords
124
Possible values
Default
PC
PC
SNTP
xxx.xxx.xxx.xxx
192.168.0.44
Possible values
Default
Auto
Auto
Off
On
Possible values
Default
☐ / ☑
Description
PC: The PC provides the time stamp.
SNTP: An SNTP server (SNTP = simple network
time protocol) in the network provides the time
stamp.
IP address of the SNTP server (enabled only when
Source = SNTP)
Description
Here, you specify whether a live image is displayed
in processing mode on the "Run" page:
Off: No live image
On: Live image is displayed
Auto: Live image is displayed load-dependent
Description
The image belonging to the next NOK signal is
saved in the EPROM. If an image is already stored
there, it is overwritten when this function is selected.
As soon as the function is enabled, as many diag-
nostics entries as you specify in the following input
box are saved in the EPROM. Existing entries are
deleted when you switch over to On. If the diagnos-
tics buffer in the EPROM reaches the number of
permanently storable diagnostic data records, no
further entries are made.
Note
Deleting takes several seconds.
Operating Manual, 05/2019, C79000-G8976-C495-02