5.1.4.7

Evaluation

If you wish to assess the code quality (marking quality), you define the quality evaluation and
the criteria in this step.
You specify the quality criteria you require for the code quality.
Table 5- 43
Evaluation
Parameter
Overall quality
Individual qualities
Depending on the determined code quality
1)
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
Possible values
Each overall quality grade
4 ... 0 or A-F (without E,
depending on the setting
in "Settings > Options >
Extras") can be assigned
a Quality evaluation of
"Good", "Fair" or "Poor".
Center offset
Size offset
Cell modulation
Border match
Axial non-uniformity
Print growth
Unused error correc-
tion
Angle of distortion
Symbol contrast
Cell size
Default
--
1)
--
1)
Description
Color coding:
"Good" = green
"Fair" = yellow
"Poor" = red
If you click on the colored box, you
can adapt the assignment.
Note
The code qualities measured during
adjustment and processing are then
colored according to the evaluation set
here.
Can only be set for Siemens DPM, only
with verification license.
First use the arrow keys to select the
qualities you require for the evaluation.
When you select a used quality by
clicking on the quality grade 4 ... 0,
you can then adapt the evaluation
(quality evaluation of "good", "fair",
"poor"). The lowest individual quality
evaluation determines the overall
evaluation of a processing procedure.
For color coding, see "Overall quali-
ty".