Starting Up Hipath 3000; Starting Up Hipath 3800; Startup Procedure; Supplying The System With Power - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

start_h3.fm

Starting Up HiPath 3000

Starting Up HiPath 3800

5.1
Starting Up HiPath 3800
This section contains information on how to start up the HiPath 3800 communication system.
Warning
7
Only authorized service personnel should start up the system.
Danger
7
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
5.1.1

Startup Procedure

Table 5-1
HiPath 3800 - Startup Procedure
Step
1.
Supplying the System with Power, page 5-2
(Plugging in the power supply cable for the system cabinet(s) and positioning the
switches for all LUNA2 power supplies to "DC-ON" –> starting system boot)
2.
Carrying Out a System Reload, page 5-6
3.
Carrying Out the Country Initialization and Selecting the Password Type, page 5-7
4.
Not for U.S.: Entering the System Number, page 5-9
5.
Customer-Specific Programming, page 5-10
6.
Performing a System Check, page 5-10
5.1.2

Supplying the System with Power

Caution (for Brazil only)
7
The use of the outlet strip with overvoltage protection with part number C39334-
Z7052-C33 is absolutely mandatory. The AC power of the system cabinet(s) must
be conducted through the outlet strip with overvoltage protection.
5-2
Startup Activity (Remarks)
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012