Connecting The Cable To The Backplane - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

Nur für den internen Gebrauch
4.1.6

Connecting the Cable to the Backplane

All cables that leave the system cabinet must be attached to the metal back panel
>
using cable ties.
Connection options
The HiPath 3800 has various connection options for connecting the peripherals:
SIVAPAC connector on the backplane for connecting the external main distribution frame
via CABLUs (prefabricated cabling units) or for connecting external patch panels (see Sec-
tion 4.1.6.4).
Connector panels with RJ45 jacks for direct connection of peripherals (see Section
4.1.6.5). The connector panels are clipped onto the SIVAPAC connectors on the back-
plane.
For U.S. only: Connector panels with CHAMP jack for direct connection of peripherals (see
Section 4.1.6.6). The connector panels are clipped onto the SIVAPAC connectors on the
backplane.
Connector panels each with two SIPAC 1 SU connectors for connecting the external mail
distribution frame MDFU-E or external patch panels using CABLUs (see Section 4.1.6.7).
The connector panels are clipped onto the SIVAPAC connectors on the backplane.
The type of connection used will be decided in consultation with the customer on conclusion of
the agreement. The cabinets will be delivered accordingly with or without clipped-on connector
panels.
Danger
7
Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4-51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents