Siemens HiPath 3000 Series Service Documentation page 251

Table of Contents

Advertisement

Nur für den internen Gebrauch
LED statuses and their meanings
Table 3-49
IVMS8, IVMS8R - LED Statuses
LED
LED
yellow
green
During Startup and Initialization
Off
Off
On
On
On
Off
Off
Flashing
Off
(500/
500 ms)
Off
On
On
Off
During Operation
Off
On
Off
Flashing
(500/
500 ms)
Flashing
Flashing
(500/
(500/
500 ms)
500 ms)
On
Off
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
1 Boot procedure (lasts approx. 8 -
12 s)
2 LED test (lasts approx. 10 s)
3 Lockout switch state signaling by
yellow LED (lasts approx. 5 s):
blocked = On
free = Off
4 Hard disk test, application startup
(depending on hard disk status,
lasts approx. 3 - 8 minutes)
5a Standby mode after successful
boot
5b Board locked or board error oc-
curred
Idle (no call)
At least one active port (call)
Lockout switch activated during a call
Board locked or board error occurred
Boards for HiPath 3000
Peripheral boards
Action
Possibly check if board was de-
activated using HiPath 3000/
5000 Manager E or lockout
switch.
Check whether board was deac-
tivated using HiPath 3000/5000
Manager E or lockout switch.
Check whether board was deac-
tivated using HiPath 3000/5000
Manager E or lockout switch.
boards.fm
3-119

Hide quick links: