HiPath 3000/5000 Manager E is used to set the signaling protocol. Settings Menu: Lines/net-
working ... –> Trunks –> (double-click) Parameters –> Template Editor:
Board type = TMDID, TIEL, TMEW2
Template: the following settings are possible:
4. E/M tieline with winkstart/delayed (= "Wink Start" protocol)
11. E/M tieline with delayed dialing (= "Delay Dial" protocol)
12. E/M tieline with immediate dialing (= "Immediate Start" protocol)
Interface type 1A (or 5) is used in all cases.
SIVAPAC connector assignment on the backplane with tie trunk traffic via interface type 1A (or
5) is shown in Table 3-162.
Connecting the Genius announcement device
The TMEW2 board may be installed on interface type 2 for connecting the Genius announce-
ment device.
TMEW2
- 48 V
E
Figure 3-112
E&M Interface Type 2
Use HiPath 3000/5000 Manager E to configure the settings for the Genius announcement de-
vice: Settings Menu: Auxiliary equipment –> Announcement.
SIVAPAC connector assignment on the backplane with a Genius announcement device con-
nected (interface type 2A) is shown in Table 3-163.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
E
SG
M
SB
Remote system/transmission
equipment with TMEW2
E
E
SG
M
SB
boards.fm
Boards for HiPath 3000
Peripheral boards
- 48 V
3-329