Siemens HiPath 3000 Series Service Documentation page 567

Table of Contents

Advertisement

Nur für den internen Gebrauch
Installing shielding covers
Please observe the following rules when installing shielding covers:
In the case of boards with no connection option on the front, a shielding cover (C39165-
A7075-B15) must be installed as these only have a plastic cover C39228-A402-C21.
These are:
SLMA24, SLMA8, SLMAE8, SLMAE200, SLMO2, SLMO8, STMD3, TM2LP, TMC16, TM-
DID/TMDID2, TMEW2
In the case of boards with a connection option on the front, a shielding cover is not installed
as these have a special shielded front panel. These are:
DIUT2, DIUN2, DIU2U, STMI2, TMCAS-2, TMANI8, SLCN, IVMNL
Empty board slots must be equipped with shielding covers at the front and at the back.
When using internal patch panels:
The number of rear shielding covers (DUA437) depends on the number of internal patch
panels used.
Example: Basic cabinet (9 slots): 4 internal patch panels ==> 5 shielding covers. Patch
panels should be handled in the same way as shielding covers.
Board slots with MDFU (CABLUs), external patch panels or with OpenEnd cabling must be
covered with additional blind panels for shielding purposes.
Install the shielding cover as follows:
1.
Insert the two bottom pins on the shielding cover into the openings provided for this pur-
pose on the slide-in shelf.
2.
Push the shielding cover in the direction of the board until it locks into position (see
Figure 4-17).
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents