inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.2.4

Installing HiPath 3500 and HiPath 3300 (19-Inch Housing)

This section contains information on how to install the HiPath 3500 and HiPath 3300 19-inch
housing. This chapter describes the standard installation procedures for the basic system. Re-
fer to Chapter 9 for information about supplementary equipment and expansions.
Danger
7
The HiPath 3500 and HiPath 3300 systems can only be operated with a closed hous-
ing.
Before opening the housing, make sure that the system is de-energized as follows:
by disconnecting the line cord attached to any connected battery pack (for
UPSC-DR only).
by disconnecting the line cord attached to any connected Powerbox PB3000.
by disconnecting the power plug.
4.2.4.1

Installation Versions

HiPath 3500 and HiPath 3300 are designed for the following types of installation:
Wall attachment (with assembly kit)
Desk installation (assembly kit includes adhesive feet)
Stick the adhesive feet to the bottom of the housing.
Installation into 19" cabinet (with assembly kits for HiPath 3500 and HiPath 3300)
These systems also support the use of Powerbox PB3000. PB3000 can accommodate four
batteries and/or an additional LUNA2 external power supply unit. The batteries guarantee un-
interruptible power supply. LUNA2 is needed if the system's internal power supply unit is insuf-
ficient. Additional information can be found in Section 9.1.3, "Inserting Powerbox PB3000".
4-110
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation