Parameter assignment / addressing
6.6 Configuring an Ethernet subnet
● Communication based on OPC UA (Unified Architecture)
● PROFINET basic services (e.g. DCP, LLDP, SNMP)
These PROFINET basic services provide uniform functions for the address assignment
and diagnostics, but do not provide PROFINET IO communication for the connection of
drives, I/O modules, etc.
Setting/reading the IP address
As of V4.4, new system functions (_setPnIpConfig/_getPnIpConfig) for setting/reading the IP
address are available. The new system functions have a larger functional scope (e.g.
temporary or permanent setting of the IP address) and support all Ethernet-based interfaces
of a SIMOTION D4x5‑2.
The previous system functions _setIpConfig/_getIpConfig only support the interfaces X127 PN/
IE (EnumInterfaceID = IE_01(0)) and X130 PN/IE‑NET (EnumInterfaceID = IE_02(1)). The
interfaces X120 PN/IE‑OP, X150 PN, and X1400 PN (CBE30‑2) cannot be used. We
recommend only using the new system functions in the future.
Routing
"Services via TCP" are supported for all Ethernet interfaces.
From the two Ethernet interfaces, S7 routing is possible to the
● PROFIBUS interfaces and
● PROFINET interfaces
● As well as between the Ethernet interfaces
IP routing from one Ethernet interface to another, as well as from the PROFINET interface to
the Ethernet interface and vice versa, is not possible.
You can find the MAC addresses on the rating plate located on the front of the
SIMOTION D4x5‑2.
See also
Further information about routing and the differences between IP and S7 routing can be found
in the
162
SIMOTION Communication System Manual.
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B