7.4 Configuring a CX32-2
4. Repeat steps 1 to 3 for each CX32‑2.
5. Save the project.
Note
Topology errors can result in a download or system power-up not being possible.
Result
The CX32‑2 is now also ready for operation (RDY LED is green, DP LED is green (in RUN
mode) or flashes green at 0.5 Hz (in STOP mode)).
7.4.5.2

Loading a project created offline to the CF card

Loading a project created offline to the CF card has the advantage of being faster than a
download.
It should be noted, however, that the first system power-up will take longer, as the SINAMICS
Integrated and CX32‑2 will perform one-off parameter calculations. These are automatically
backed up on the CF card.
Requirement
● You will need a card reader for the SIMOTION D4x5‑2 CF card.
● Your project, including all SINAMICS Integrated and CX32‑2 drive components, must have
been configured already (see Preparing for configuration (Page 212)).
● The actual topology must correspond with the reference topology.
Procedure
1. Select "Load to file system" in the SIMOTION D4x5‑2 context menu.
2. Select "Normal save" and click the "Select target" button. Select your card reader's drive
and confirm with "OK".
3. If a project has already been saved to the CF card, the message "Memory card file already
exists. Do you want overwrite this file?" appears. Confirm the message with "Yes".
4. Once the project has been subsequently transferred to the CF card, insert the card into the
disconnected SIMOTION D4x5‑2. Switch on the power supply of the D4x5‑2 and the
connected components.
5. After a successful power-up, the RDY LED of the D4x5‑2 and the CX32‑2 will be green, as
will the DP LED of the CX32‑2.