Permissible Combinations - Siemens SIMOTION D4x5-2 Commissioning And Hardware Installation Manual

Hide thumbs Also See for SIMOTION D4x5-2:
Table of Contents

Advertisement

Commissioning (software)
7.22 Migration of SIMOTION D4x5 to SIMOTION D4x5-2
Keyword
Hardware
Installation options
7.22.2

Permissible combinations

DRIVE-CLiQ components
Some "older" DRIVE‑CLiQ components can no longer be used with the SIMOTION D4x5‑2/
CX32‑2.
Table 7-22
DRIVE-CLiQ components
Single Motor Modules (SMM)
Double Motor Modules (DMM)
Line Modules (ALM/SLM)
Chassis power units
(Line Modules, Motor Modules, Pow‐
er Modules)
SMC30 Sensor Module Cabinet
TM31/TM41 Terminal Modules
SME20/25 Sensor Modules External
CUA31 Control Unit Adapter
Power Modules (chassis)
334
Explanation
The following changes have been made because of the hardware innovations:
● CF card under a cover (previously open access)
● Additional and slightly differently arranged operator control and display elements
● Modified connectors (larger cable cross-section, screw connection on the 24 V terminal
block, etc.)
● D445‑2 DP/PN and D455‑2 DP/PN have a heat sink so that the spacers (with the exception
of external heat dissipation) cannot be disassembled as for the D445‑1. See also Section
Mounting a SIMOTION D4x5-2 (Page 36).
● A double fan/battery module is always required for D4x5-2 Control Units. See Section
Cooling the SIMOTION D4x5-2 (Page 117).
● Controller Extensions (CX) for D4x5 can only be used for the D435 and D445/D445‑1; with
the D4x5‑2, all Control Units support the use of CX32‑2 Controller Extensions.
For the SIMOTION D4x5 Control Units, it was possible to mount the Control Unit directly on
the Line Module via lateral mounting elements. This mounting option is no longer offered for
D4x5‑2 Control Units because of their higher weight. This mounting option is now only avail‐
able for the CX32‑2 Controller Extension and the CU320‑2 Control Unit.
DRIVE‑CLiQ components that cannot be used with the D4x5‑2/CX32‑2
Notes
6SL31*
(all Motor Modules Booksize Compact
6SL34* can be used)
6SL313*
The following can generally be used:
● All BLM (6SL313*)
● SLM (6SL313*) 5 and 10 kW
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Ending of the
Article No.
< 3
< 3
< 3
< 2
< 1
< 3
< 1
< 3
SIMOTION D4x5-2