5. DIAGNOSTIC TEST OPERATION
5.4.9.3 Sensor Information
Information about CPU sensor and HDD sensor is displayed here.
(1) Operation procedure
1. Select the Sensor Info(3) button on the System Information Menu screen.
2. Click the Read Sensor button. When the sensor information is successfully read, it is written into the
edit box.
3. When the sensor information on the screen is allowed, click the OK button. If it is not allowed, click on
the NG button to restore the display to the previous screen.
(2) Error code
Result
Error Code
-1
(3) Corrective action
Error
The [NG] button is
clicked.
<< Preliminary version >>
(Check the original screen)
Error Code Ex
0
Make sure the CPU fan performs correctly.
If dust particles are gathered in the CPU fan, remove and clean it.
0
The [NG] button is clicked.
Cause & Measure
5- 57
5.4 Serviceman Diagnostic Test Program
 
Remarks
EO18-12017