2. OPERATION
Class No. Symbol
38
VIC
Speed integral compensation
Used to set the constant of integral compensation.
39
VDC
Speed differential compensation:
Used to set the differential compensation value.
For manufacturer setting
40
Must not be change
41
*DIA
Input signal automatic ON selection:
Used to set automatic ON of SON, LSP and LSN.
0
42
*DI1
Input signal selection 1:
Used to assign the control mode changing signal input
pins and to set the clear signal.
0
Name and Function
Servo on signal (SON) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo:
amplifier.
(No need of external wiring)
Forward rotation stroke end signal
(LSP) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Reverse rotation stroke end signal (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
0
Control change signal (LOP) in-
put pin assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/spe-
ed, speed/torque or torque/posi-
tion change mode.
Set Value
Connector Pin No.
0
CN1B – 5
1
CN1B – 14
2
CN1A – 8
3
CN1B – 7
4
CN1B – 8
5
CN1B – 9
Clear signal (CR) selection
0: Droop pulses are cleared on the
leading edge.
1: Always cleared while on.
2– 45
Control
Initial
Setting
Unit
Value
Range
ms
20
1 to 1000
0 to 1000
980
0000
0000h
P • S • T
to
0111h
0003
0000h
to
0015h
P • S • T
Mode
P • S
P • S
P • S
P/S
2
S/T
T/P