Mitsubishi Electric MELSERVO MR-J2-A Product Specifications And Installation Manual page 76

Servo motors and servo amplifiers
Table of Contents

Advertisement

2. OPERATION
Class No. Symbol
38
VIC
Speed integral compensation
Used to set the constant of integral compensation.
39
VDC
Speed differential compensation:
Used to set the differential compensation value.
For manufacturer setting
40
Must not be change
41
*DIA
Input signal automatic ON selection:
Used to set automatic ON of SON, LSP and LSN.
0
42
*DI1
Input signal selection 1:
Used to assign the control mode changing signal input
pins and to set the clear signal.
0
Name and Function
Servo on signal (SON) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo:
amplifier.
(No need of external wiring)
Forward rotation stroke end signal
(LSP) input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Reverse rotation stroke end signal (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
0
Control change signal (LOP) in-
put pin assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/spe-
ed, speed/torque or torque/posi-
tion change mode.
Set Value
Connector Pin No.
0
CN1B – 5
1
CN1B – 14
2
CN1A – 8
3
CN1B – 7
4
CN1B – 8
5
CN1B – 9
Clear signal (CR) selection
0: Droop pulses are cleared on the
leading edge.
1: Always cleared while on.
2– 45
Control
Initial
Setting
Unit
Value
Range
ms
20
1 to 1000
0 to 1000
980
0000
0000h
P • S • T
to
0111h
0003
0000h
to
0015h
P • S • T
Mode
P • S
P • S
P • S
P/S
2
S/T
T/P

Advertisement

Table of Contents
loading

Table of Contents