Mitsubishi Electric MELSERVO MR-J2-A Product Specifications And Installation Manual page 89

Servo motors and servo amplifiers
Table of Contents

Advertisement

3.WIRING
(2) Signals
Symbol
L1, L2, L3
Main circuit power supply
L11, L21
Control circuit power supply
P, C, D
Regenerative brake option
U, V, W
Servo motor output
N
Protective earth (PE)
(3) How to use the control circuit terminal block (Phoenix Contact make)
1) Termination of the cables
Solid wire:
the cable can be used as it is. (Cable
size: 0.2 to 2.5mm
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this
(Bar terminal ferrule with insulation sleeve)
Signal
Main circuit power input terminals
Supply L1, L2 and L3 with the following power:
For single-phase 230VAC, connect the power supply to L1/L2
and leave L3 open.
Power supply
3-phase 200 to 230VAC, 50/60Hz
(Note) Single-phase 230VAC, 50/60Hz
Single-phase 100 to 120VAC, 50/60Hz
Note: Cannot be used for combination with the servo motor HC-SF52.
Control circuit power input terminals
Supply L11 and L21 with the following power:
Power supply
Single-phase 200 to 230VAC, 50/60Hz
Single-phase 100 to 120VAC, 50/60Hz
L11 and L21 should be in phase with L1 and L2, respectively.
Regenerative brake option connection terminals
C and D are factory-connected.
When using the regenerative brake option, always remove
wiring from across P-D and connect the regenerative brake
option across P-C.
Servo motor power output terminals
Connect to the servo motor power supply terminals (U, V, W).
Do not connect.
Ground terminal
Connect this terminal to the protective earth (PE) terminals
of the servo motor and control box for grounding.
After the sheath has been stripped,
2
)
time, take care to avoid a short caused by the loose wires of the core
and the adjacent pole. Do not solder the core as it may cause a con-
tact fault. (Cable size: 0.2 to 2.5mm
Alternatively, a bar terminal may be used to put the wires together.
(Phoenix Contact make)
Bar terminal for 1 cable
Cable Size
Bar Terminal Type
2
[mm ]
For 1 cable
AWG
Al0.25-6YE
0.25
24
Al0.25-8YE
Al0.5-6WH
0.5
20
Al0.5-8WH
Al0.75-6GY
0.75
18
Al0.75-8GY
Al1-6RD
1
18
Al1-8RD
Al1.5-6BK
1.5
16
Al1.5-8BK
Al2.5-8BU
2.5
14
Al2.5-8BU-1000
Description
Servo amplifier MR-J2-10A
to 70A
L1•L2•L3
L1•L2
Servo amplifier
MR-J2-10A
to 350A
L11•L21
2
)
Bar terminal for 2 cables
(Twin ferrule with insulation sleeve)
Crimping
Tool
For 2 cables
Al-TWIN2 0.75-8GY
Al-TWIN2 0.75-10GY
CRIMPFOX-UD6
Al-TWIN2 1-8RD
Al-TWIN2 1-10RD
Al-TWIN2 1.5-8BK
Al-TWIN2 1.5-12BK
Al-TWIN2 2.5-10BU
Al-TWIN2 2.5-13BU
3– 4
MR-J2-100A
MR-J2-10A1
to 350A
to 40A1
L1•L2
MR-J2-10A1
to 40A1
L11•L21
Approx. 10mm

Advertisement

Table of Contents
loading

Table of Contents