Minimum Startup Configuration - Fujitsu PRIMERGY CX400 S1 Upgrade And Maintenance Manual

Server enclosure
Table of Contents

Advertisement

13.3

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
1 Server node CX250 S1 or
CX270 S1
1 PSU
Table 8: Minimum startup configuration - components
Cable
Power cable
Table 9: Minimum startup configuration - cables
Ê Shut down the server as described in section
node" on page
Ê Remove the AC power cord from the cable tie and disconnect it from the
system as described in section
Ê Take the system down to its minimum startup configuration.
Ê Reconnect the AC power cord to the power supply module and secure it with
a cable tie as described in section
Ê Switch on the server as described in section
node(s)" on page
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
CX400 S1
Notes and reference
Notes and reference
41.
"Disconnecting the power cord" on page
75.
Upgrade and Maintenance Manual
"Shutting down the server
"Connecting the power cord" on page
"Switching on the server
Appendix
42.
73.
209