Replacing A 3.5-Inch Hdd Module; Required Tools; Preliminary Steps - Fujitsu PRIMERGY CX400 S1 Upgrade And Maintenance Manual

Server enclosure
Table of Contents

Advertisement

Hard disk drives / solid state drives
7.3.4

Replacing a 3.5-inch HDD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "PRIMERGY CX400 S1 Server
Enclosure Operating manual".
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
7.3.4.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
7.3.4.2

Preliminary steps

Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
or from the ServerView Suite DVD 2 supplied with your PRIMERGY
server.