4.4.2

Removing the server node CX270 S1

I
The CX400 S1 system must always run with closed node bays. It is only
allowed to leave a bay open for a limited time in case of repairing a server
node (for example). In this case the node bay must be closed within one
hour. In the meantime all remaining server nodes run in throttling mode
(with reduced performance).
V
CAUTION!
Shut down the server node and disconnect all external cables.
Follow the safety instructions in the chapter
on page
Figure 8: Removing the server node CX270 S1
Ê Undo the locking mechanism (1) of the release lever and pull the server
node out of the slot (2).
CX400 S1
31.
Upgrade and Maintenance Manual
Basic hardware procedures
"Important information"