Leak Alert!
If hydraulic fluid leaks during operation, the fluid level in
OIL LEVEL SENSOR
LEAK DETECTOR
the main hydraulic tank drops. This causes the oil level
(lowered/closed)
TANK
sensor float to lower, closing the alarm circuit. The alarm
will sound and the console indicator light will illuminate
SIGHT
after a one (1) second time delay.
ALARM
GAUGE
(on)
NOTE: During normal operation, with cutting units low-
ered, approximately 5 oz (148 ml) of hydraulic fluid will
leak before the oil level sensor float closes the alarm cir-
cuit and activates the alarm.
SOLENOID
VALVE
(closed)
MAIN HYDRAULIC TANK
Figure 4