Toro Electronic Controller (Tec) - Toro Greensmaster TriFlex 3320/3420 Service Manual

Ride-on lawnmowers
Table of Contents

Advertisement

Toro Electronic Controller (TEC)

Greensmaster TriFlex Hybrid machines use a Toro Elec-
tronic Controller (TEC) to monitor the condition of vari-
ous switches (inputs) and then direct electrical power
output to allow certain machine functions. The controller
is attached to the frame under the operator seat (Fig.
70). TEC inputs and outputs on your Greensmaster can
be checked with the Hand Held Diagnostic Display (see
Hand Held Diagnostic Display in the Troubleshooting
section of this chapter) or InfoCenter Display (see
InfoCenter Display in this chapter).
Inputs from the ignition, neutral, parking brake, seat,
joystick, mow, backlap and engine oil pressure are all
monitored by the TEC controller. TEC inputs on Green-
smaster 3420 machines also include the alternator, en-
gine temperature sender and optional hydraulic
temperature sender (if equipped). TEC inputs on
Greensmaster 3320 machines also include the leak de-
tector sensor if equipped with the optional Turf Defen-
TM
der
Leak Detector.
On all Greensmaster TriFlex Hybrid machines, TEC
controller current output to the lift circuit hydraulic valve
solenoid coils (S1, S2, S3 and S4) and console diagnos-
tic light (if equipped) are controlled based on the inputs
received by the controller. TEC outputs on Greensmas-
ter 3320 machines also include the start solenoid, fuel
solenoid, charge circuit relay, kill relay and optional Turf
TM
Defender
Leak Detector indicator light and alarm.
TEC outputs on Greensmaster 3420 machines also in-
clude the start relay, glow relay, fuel pump, engine run
solenoid (hold coil), fan relay and console indicator
lights (if equipped).
If the controller detects a malfunction in any of the con-
trolled circuits, the diagnostic light or InfoCenter Display
can be used to identify the fault.
The diagram in Figure 71 depicts the connection termi-
nal functions of the TEC controller. A fifty (50) pin wire
harness connector attaches to the controller. The con-
nector pins are listed in the diagram. Note that electrical
power for controller outputs is provided through three (3)
connectors each protected with a 7.5 amp fuse.
Because of the solid state circuitry built into the control-
ler, there is no method to test it directly. The controller
may be damaged if an attempt is made to test it with an
electrical test device, such as a digital multimeter.
IMPORTANT: Before welding on the machine, dis-
connect both battery cables from the battery, dis-
connect the wire harness connector from the TEC
controller and disconnect the terminal connector
from the alternator. This will prevent damage to the
electrical system of your Greensmaster.
Greensmaster 3320/3420
1. TEC controller location
12V POWER
(7.5A FUSES)
12V LOGIC
POWER
(2 AMP FUSE)
IGNITION
SWITCH
INPUTS
DIGITAL
INPUTS
(OPEN/
CLOSED)
ANALOG
INPUTS
(VARIABLE)
Page 6 - - 57
1
2
Figure 70
2. Seat platform
DIAGNOSTIC
Figure 71
Electrical System
OUTPUTS
(PWR2)
OUTPUTS
(PWR3)
OUTPUTS
(PWR4)
DISPLAY
CAN BUS
GROUND

Hide quick links: