3. Measure coil resistance between terminals 85 and
86 with a multimeter (ohms setting) (Fig. 76). Resist-
ance should be approximately 72 ohms.
4. Connect multimeter (ohms setting) leads to relay ter-
minals 30 and 87. Ground terminal 86 and apply +12
VDC to terminal 85. The relay should make and break
continuity between terminals 30 and 87 as +12 VDC is
applied and removed from terminal 85.
Greensmaster 3320/3420
5. Disconnect voltage and leads from the relay termi-
nals. Replace relay if necessary.
6. After testing is completed, secure relay to bracket
and connect wire harness electrical connector to relay.
7. Install right side cover next to operator seat.
Page 6 - - 61