Ignition Switch (Serial Number Above 312000000)

The ignition (key) switch is located on the control panel
and has three (3) positions: STOP, RUN and START
(Fig. 37). The Toro Electronic Controller (TEC) monitors
the operation of the ignition switch.
NOTE: The engine can only be started when the func-
tional control lever is in the NEUTRAL position and ei-
ther the seat is occupied or the parking brake is
engaged. Also, the TEC controller limits engine crank-
ing time to thirty (30) seconds.
Testing
1. Park machine on a level surface, lower cutting units,
engage parking brake and stop engine. Remove key
from ignition switch.
2. Before disconnecting the ignition switch for testing,
the switch and its circuit wiring should be tested as a
TEC electrical input using the Hand Held Diagnostic Dis-
play (see Hand Held Diagnostic Display in the Trouble-
shooting section of this chapter) or InfoCenter Display
(see InfoCenter Display in this chapter). If input testing
verifies that the ignition switch and circuit wiring are
functioning correctly, no further ignition switch testing is
necessary. If, however, input testing determines that the
ignition switch and circuit wiring are not functioning cor-
rectly, proceed with the following ignition switch testing
procedure.
3. Remove console cover from console assembly to
gain access to ignition switch (see Control Console Dis-
assembly in the Service and Repairs section of Chapter
7 -- Chassis).
4. Make sure ignition switch is in the OFF position. Dis-
connect wire harness connector from ignition switch.
5. The ignition switch terminals are identified in Figure
37 and the circuitry of the switch is shown in the chart in
Figure 38. With the use of a multimeter (ohms setting),
the switch functions can be tested to determine whether
continuity exists between the various terminals for each
switch position. Verify continuity between switch termi-
nals.
Greensmaster 3320/3420
6. Replace ignition switch if testing determines that it is
faulty.
7. If the ignition switch tests correctly and a circuit prob-
lem still exists, check wire harness (see Electrical Sche-
matics and Wire Harness Drawings in Chapter 10 --
Foldout Drawings).
8. After testing is complete, connect machine wire har-
ness connector to ignition switch. Secure console cover
to machine with removed fasteners.
STOP
FRONT VIEW
SWITCH
POSITION
STOP
RUN
START
NOTE: Ignition switch terminals 1 and 6 are connected
internally. Terminals 4 and 5 are also connected internal-
ly. These terminals should have continuity regardless of
switch position.
Page 6 - - 41
RUN
START
REAR VIEW
Figure 37
CIRCUITS
1 + 6
1 + 3 + 4 + 5 + 6
1 + 2 + 4 + 5 + 6
Figure 38