Mitsubishi Electric FR-A700 Technical Manual page 100

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

4) FR-A7AZ
Terminal
Terminal Name
Symbol
Bipolar analog output
DA1
terminal
High resolution input
6
terminal
5
Common terminal
TH1
Thermistor input 1
TH2
Thermistor input 2
Thermistor calibration
SW2
status switch
(2) 16Bit digital input connection example
A700
F700
E700
1) Relay contact signal input
Thousand's place
Hundred's place
Ten's place
Unit's place
2) Open collector signal input
(Sink logic
)
*3
QY41 type
transistor
Thousand's place
output unit
*2
Hundred's place
Ten's place
Unit's place
Reading command
Rating, etc.
Output voltage : -10 to +10VDC
Frequency setting resolution : 0.01Hz/0
to 60Hz (-10 to +10V)(0.015Hz/0 to 60Hz
when option is not mounted)
Torque setting resolution : 0.024%/0 to
100% (-10 to +10V)(0.1%/0 to 100%
when option is not mounted)
Input resistance : 10k
±
Maximum input voltage :
*4
(sink logic
*3
)
FR-A7AX
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X0
DY
SD
*1
Inverter
*5
B20
FR-A7AX
X15
B19
X14
B18
X13
B17
X12
B16
X11
B15
X10
B14
X9
B13
X8
B12
X7
B11
X6
B10
X5
B9
X4
B8
X3
B7
X2
B6
X1
B5
X0
A5
DY
B01,B02
PC
*1
A01,A02
Inverter
*2
Connect a DC indicator (
Change the monitor to be output with [Pr.838].
±
Terminal for 0 to
analog voltage input. Use [Pr. 406 ] High
resolution analog input selection to select
terminal function.
20VDC
Common terminal of terminal 6 and the DA1.
Enter thermistor output signal for the motor dedi-
cated to vector control (SF-V5RU)
When calibrating at installation, change the
switch to place the inverter in calibration status.
*1
Use terminals SD or PC on the inverter.
*2
AY41 type unit requires 24VDC power.
Example of connection with the output module (AY41
type) of Mitsubishi programmable controller. Refer to the
output module manual for details of the output module.
*3
The control logic is the same as that of the inverter
(factory-set to sink). When the logic of the inverter is
changed to source, the option logic also switches to
source. To change the control logic, refer to page 40.
*4
As the input signals are at low level, use two parallel
micro signal contacts or a twin contact for relay contact
inputs to prevent a contact fault.
Micro signal contacts
*5
A transistor of the following specifications should be
selected for the open collector signal:
Electrical characteristics of the transistor used
• Ic ≥ 10mA
• Leakage current: 100µA or less
• VCE ≥ 30V
• When Ic ≥ 10mA, VCE(sat) voltage 3V or less.
93
SPECIFICATIONS
Description
±
10VDC).
10VDC high resolution (16bit)
Twin contacts
Refer to
Page
345
43, 217,
283, 291,
301, 304,
320, 323,
335
1
50