Mitsubishi Electric FR-A700 Technical Manual page 278

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

(3) Selection of clear signal (CLR signal) [Pr.
429]
Use this function to make a drooping pulse 0 for
home position operation, etc.
When [Pr. 429 = 0], the deviation counter is cleared at
the edge of turning ON of the clear signal (CLR). The
CLR signal turns ON in synchronization with the zero
pulse signal of encoder for home position operation,
etc. and clears the deviation counter.
When [Pr. 429 = 1] (initial value), the deviation
counter is cleared while the clear signal (CLR) in ON.
For the terminal used for CLR signal input, set 69 in
any of [Pr. 178 to Pr. 189
selection] to assign the function.
When [Pr. 429 = 0]
Deviation counter
image
When [Pr. 429 = 1] (initial value)
Deviation counter
image
CLR
Input terminal function
ON
CLR
Counter clear at the edge of
turning ON of the signal
ON
Counter clear while ON
(4) Pulse monitor selection [Pr. 430]
The status of various pulses during running are
displayed.
Set [Pr. 52 DU/PU main display data selection = 6] to
display output frequency monitor.
Count the number of pulses when the servo is ON.
The cumulative pulse value is cleared when the base
is shut off or the clear signal (CLR) is turned ON.
[Pr. 430]
setting
0
The cumulative
command pulse value is
1
displayed.
2
The cumulative feedback
pulse value is displayed.
3
4
The droop pulses are
displayed.
5
9999
Frequency monitor is displayed. (initial value)
312
PARAMETER
Display Range
Description
FR-DU07
Lower 4
digits
Upper 4
digits
Lower 4
digits
Upper 4
digits
Lower 4
digits
Upper 4
digits
FR-PU04
FR-PU07
Lower 5
digits
Upper 5
digits
Lower 5
digits
Upper 5
digits
Lower 5
digits
Upper 5
digits

Hide quick links: