1.4.34 Safety stop function (S1, S2, SO,SC)
This inverter has two lines of input terminal for inverter output shutoff, and one monitor output terminal for monitoring output
shutoff state. Using these terminals, compliance with Machinery Directive in EU becomes more accessible.
*1
At initial state, terminal S1 and S2 are shorted to terminal SC with a shorting wire. When using the safety stop function, remove
this shorting wire, and connect to a safety relay module.
*2
Set "80 (positive logic) or 180 (negative logic)" in [Pr. 190, Pr. 192 (output terminal function selection)] when assigning safety
monitor output signal (SAFE) to other terminals.
* Changing the terminal assignment using [Pr. 190, Pr. 192 (output terminal function selection)] may affect the other functions. Make
setting after confirming the function of each terminal.
D700
(D700)
95
SPECIFICATIONS