Terminal
Terminal
Symbol
Name
A1, B1,
Relay output
terminal 1
C1
Contact capacity :
(Fault output
(A, B, C)
230VAC 0.3A (power factor
terminal)
0.4)
*2
30VDC 0.3A
A2, B2,
Relay output
terminal 2
C2
*2
Inverter
RUN
running
*2
terminal
Up to
Open collector output
SU
frequency
*2 *3
terminal
A700
Permissible load: 24VDC 0.1A
(Maximum 27VDC)
Overload
(Maximum voltage drop at ON
alarm
OL
*2 *3
status is 2.8V)
terminal
E700
Instantaneo
Permissible load: 24VDC 0.1A
us power
IPF
*2 *3
(Maximum 27VDC)
failure
(Maximum voltage drop at ON
terminal
status is 3.4V)
Frequency
detection
FU
*2 *3
terminal
Open
collector
SE
output
common
terminal
Isolated by photocoupler
Permissible load current :
Terminal for
A700
meter
E700
1440 pulse/s at 60Hz
FM
*5
NPN open collector output
NPN open
Permissible load current :
collector
80mA
output
Maximum output pulse:
terminal
50kpulse/s
Non-isolated
0 to 10VDC
Analog
Permissible load current : 1mA
AM
signal output
*6
(load impedance 10k
terminal
more)
Resolution : 8 bit
Conforming standard : EIA-485
(RS-485)
Transmission form : Multidrop
PU
link
connector
Communication speed : 4800
to 38400bps
Overall extension : 500m
TXD+ Inverter
transmission
Conforming standard : EIA-485
TXD-
terminal
(RS-485)
Transmission form: Multidrop
RXD+ Inverter
link
reception
Communication speed : 300 to
RXD-
terminal
38400bps
Ground
Overall extension : 500m
SG
terminal
Rating, etc.
Application Explanation
1 changeover contact output
indicates that the inverter fault
occurs.
When a fault occurs, terminals B-C
are open (A-C are closed). In the
normal state, terminals B-C are
closed (A-C are open).
When this signal is output, the motor
coasts.
1 changeover contact output
Switched low when the inverter
output frequency is equal to or higher
than the starting frequency (initial
value 0.5Hz). Switched high during
stop or DC injection brake
operation.*5
Switched low when the output
frequency reaches within the range of
10% (initial value) of the set
frequency. Switched high during
acceleration/deceleration and at a
F700
stop.*5
Switched low when stall prevention is
activated by the stall prevention
function. Switched high when stall
prevention is cancelled. *5
D700
Switched low when the protective
circuit is activated due to an
instantaneous power failure and
under voltage. *5
This open collector output is switched
low when the output frequency
reaches or exceeds the detection
frequency set in [Pr. 42] (initial value
is 6Hz) and [Pr. 43] (initial value is
9999 (same as the [Pr. 42] setting))
and is high when it is less than the
detection frequency.
Common terminal for terminals RUN,
SU, OL, IPF, and FU.
Isolated from terminals SD and 5.
Do not earth (ground).
The output voltage is a 8VDC pulse-
shaped waveform.
Connect a 1mA moving-coil type DC
: 2mA
ammeter.
F700
When the frequency is as set in [Pr.
: 1mA
D700
55] (initial value is 60Hz), the output
pulse frequency is 1440pulse/s.
Terminal FM is used as high speed
pulse train output terminal of open
collector output.
To use as pulse train output terminal,
the [Pr. 291] setting needs to be
changed.
Factory-set to provide 10VDC at full-
scale value, which is proportional to
the monitor value.
When the frequency is as set in [Pr.
or
55] (initial value is 60Hz), the output
voltage is 10VDC.
With the PU connector,
communication can be made through
RS-485. (1:1 connection only)
With the RS-485 terminals,
communication can be made through
RS-485.
*5
32
SPECIFICATIONS
Available Inverters
A700
F700
E700
D700
Refer
to
Page
65
66
70
69
68
71
80
78
352
80
81
83