Mitsubishi Electric FR-A700 Technical Manual page 164

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
Setting Range
0 to 5, 7, 8, 10, 12, 14, 16,
178
STF terminal function selection
18, 24, 25, 60, 62, 65 to 67,
9999
0 to 5, 7, 8, 10, 12, 14, 16,
179
STR terminal function selection
18, 24, 25, 61, 62, 65 to 67,
9999
180
RL terminal function selection
0 to 5, 7, 8, 10, 12, 14, 16,
181
RM terminal function selection
18, 24, 25, 62, 65 to 67,
9999
182
RH terminal function selection
0, 1, 3, 4, 7, 8, 11 to 16, 25,
26, 46, 47, 64, 70, 80, 90,
91, 93, 95, 96, 98, 99, 100,
101, 103, 104, 107, 108, 111
190
RUN terminal function selection
to 116, 125, 126, 146, 147,
164, 170, 180, 190, 191,
193, 195, 196, 198, 199,
9999
0, 1, 3, 4, 7, 8, 11 to 16, 25,
26, 46, 47, 64, 70, 80, 90,
91, 95, 96, 98, 99, 100, 101,
192
A,B,C terminal function selection
103, 104, 107, 108, 111 to
116, 125, 126, 146, 147,
164, 170, 180, 190, 191,
195, 196, 198, 199, 9999
232
Multi-speed setting (speed 8)
0 to 400Hz, 9999
233
Multi-speed setting (speed 9)
0 to 400Hz, 9999
234
Multi-speed setting (speed 10)
0 to 400Hz, 9999
235
Multi-speed setting (speed 11)
0 to 400Hz, 9999
236
Multi-speed setting (speed 12)
0 to 400Hz, 9999
237
Multi-speed setting (speed 13)
0 to 400Hz, 9999
238
Multi-speed setting (speed 14)
0 to 400Hz, 9999
239
Multi-speed setting (speed 15)
0 to 400Hz, 9999
-
240
Soft-PWM operation selection
0, 1
-
241
Analog input display unit switchover
0, 1
-
244
Cooling fan operation selection
0, 1
245
Rated slip
0 to 50%, 9999
246
Slip compensation time constant
0.01 to 10s
Constant-power range slip compensation
247
0, 9999
selection
-
249
Earth (ground) fault detection at start
0, 1
0 to 100s, 1000 to 1100s,
-
250
Stop selection
8888, 9999
-
251
Output phase loss protection selection
0, 1
255
Life alarm status display
(0 to 15)
256
Inrush current limit circuit life display
(0 to 100%)
257
Control circuit capacitor life display
(0 to 100%)
258
Main circuit capacitor life display
(0 to 100%)
259
Main circuit capacitor life measuring
0, 1 (2, 3, 8, 9)
-
260
PWM frequency automatic switchover
0, 1
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
1
60
1
61
1
0
1
1
1
2
1
0
1
99
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
1
1
0
1
1
0.01%
9999
0.01s
0.5s
1
9999
1
0
0.1s
9999
1
1
1
0
1%
100%
1%
100%
1%
100%
1
0
1
0
194
Instruction Code
[Pr.]
37
178
12
37
179
13
37
180
14
37
181
15
37
182
16
61
190
1E
61
192
20
216
232
28
216
233
29
216
234
2A
216
235
2B
216
236
2C
216
237
2D
216
238
2E
216
239
2F
430
240
30
217
241
31
431
244
34
391
245
35
391
246
36
391
247
37
381
249
39
330
250
3A
380
251
3B
364
255
3F
364
256
40
364
257
41
364
258
42
364
259
43
430
260
44
Control Mode-based
Correspondence Table
General-purpose
V/F control
magnetic-flux
vector control
92
2
93
2
94
2
95
2
96
2
9E
2
A0
2
A8
2
A9
2
AA
2
AB
2
AC
2
AD
2
AE
2
AF
2
B0
2
B1
2
B4
2
B5
2
B6
2
B7
2
B9
2
BA
2
BB
2
BF
2
C0
2
C1
2
C2
2
C3
2
C4
2
194
PARAMETER
×
×
×
×
×
×
2
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: