Mitsubishi Electric FR-A700 Technical Manual page 425

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

2.21.6 Modbus-RTU communication [Pr.117*, 118*, 120*, 122*, 331*, 332*, 334*, 343,
502*, 539*, 549]
Communication operation and parameter setting can be
performed using the Modbus-RTU communication protocol
from the RS-485 terminal in
connector in
E700
D700
Set [Pr. 549 Protocol selection = 1] to use Modbus RTU
protocol.
If a communication option is installed while [Pr. 550 NET
mode operation command source selection =9999] (initial
value) in
, command source (for example,
A700
F700
run command) at RS-485 terminal becomes invalid.
[Pr.]
Name
117
RS-485
communication station
number
331
118
RS-485
communication speed
332
120
RS-485
communication parity
check selection
334
Communication error
343
122
Modbus-RTU
communication check
time interval
539
Stop mode selection
502
at communication
error
549
Protocol selection
*1
When Modbus-RTU communication is performed from the master with address 0 (station 0) set, broadcast communication is
selected and the inverter does not send a response message to the master. When response from the inverter is necessary, set
[Pr. 117, 331 RS-485 communication station
*2
Not used in Modbus RTU communication.
common
(common)
(*[Pr. 117, 118, 120, 122, 502] are not used in
(*[Pr. 331, 332, 334, 539] are not available for
or the PU
A700
F700
.
Setting
Initial Value
Range
0
0
1 to 247
3, 6, 12, 24,
96
48, 96, 192,
384
0
1
2
2
0
A700 F700
0
9999
0 to 999.8s Set the interval of communication check time.
E700
D700
9999
0
0, 3
E700
0
D700
0
1
2
0
0
1
0] (initial value is 0). Some functions are invalid for broadcast communication.
Change the setting to [Pr. 550 = 1] in that case. (Refer to
page 436)
When NET mode command source is at the PU connector
in
( [Pr. 551 PU mode operation command source
D700
selection
2]), operation by Modbus RTU communication is
available.
When NET mode command source is at the PU connector
in
([Pr. 550 NET mode operation command source
E700
selection = 2 or 9999 (initial value)], no communication
option), operation by Modbus RTU communication is
available. (Refer to page 436)
Description
No reply to the master
*1
Specifies the inverter station number.
Set the inverter station numbers when two or more
inverters are connected to one personal computer.
Set the communication speed.
The setting value
100 equals the communication
speed.
For example, the communication speed is 9600bps
when the setting value is 96.
Without parity check
Stop bit length 2bit
With odd parity check
Stop bit length 1bit
With even parity check
Stop bit length 1bit
Displays the number of communication errors during
Modbus-RTU communication.
Modbus-RTU communication can be made, but the
inverter will come to trip in the NET operation mode.
No communication check
At Fault
Fault
Indication
Occurrence
Output
Coasts to
E.PUE
Output
stop
Decelerates
After stop
Output after
to stop
E.PUE
stop
Decelerates
After stop
Without
to stop
E.PUE
output
Mitsubishi inverter (computer link operation) protocol
Modbus-RTU protocol
459
PARAMETER
.)
A700
F700
.)
E700
D700
Available
Inverters
A700
E700
F700
D700
*2
*2
*2
*2
At Fault
Removal
Stop
(E.PUE)
*2
Stop
(E.PUE)
Automatic
restart
functions
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents