Mitsubishi Electric FR-A700 Technical Manual page 152

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
Setting Range
24
Multi-speed setting (speed 4)
0 to 400Hz, 9999
25
Multi-speed setting (speed 5)
0 to 400Hz, 9999
26
Multi-speed setting (speed 6)
0 to 400Hz, 9999
27
Multi-speed setting (speed 7)
0 to 400Hz, 9999
Acceleration/deceleration pattern
-
29
0, 1, 2
selection
-
30
Regenerative function selection
0, 1, 2
31
Frequency jump 1A
0 to 400Hz, 9999
32
Frequency jump 1B
0 to 400Hz, 9999
33
Frequency jump 2A
0 to 400Hz, 9999
34
Frequency jump 2B
0 to 400Hz, 9999
35
Frequency jump 3A
0 to 400Hz, 9999
36
Frequency jump 3B
0 to 400Hz, 9999
-
37
Speed display
0, 0.01 to 9998
-
40
RUN key rotation direction selection
0, 1
41
Up-to-frequency sensitivity
0 to 100%
42
Output frequency detection
0 to 400Hz
Output frequency detection for reverse
43
0 to 400Hz, 9999
rotation
44
Second acceleration/deceleration time
0 to 3600/360s
45
Second deceleration time
0 to 3600/360s, 9999
46
Second torque boost
0 to 30%, 9999
47
Second V/F (base frequency)
0 to 400Hz, 9999
48
Second stall prevention operation current
0 to 200%, 9999
51
Second electronic thermal O/L relay
0 to 500A, 9999
0, 5, 7 to 12, 14, 20, 23 to
52
DU/PU main display data selection
25, 52 to 57, 61, 62, 100
1 to 3, 5, 7 to 12, 14, 21, 24,
54
FM terminal function selection
52, 53, 61, 62
55
Frequency monitoring reference
0 to 400Hz
56
Current monitoring reference
0 to 500A
57
Restart coasting time
0, 0.1 to 5s, 9999
58
Restart cushion time
0 to 60s
-
59
Remote function selection
0, 1, 2, 3
-
60
Energy saving control selection
0, 9
61
Reference current
0 to 500A, 9999
62
Reference value at acceleration
0 to 200%, 9999
63
Reference value at deceleration
0 to 200%, 9999
-
65
Retry selection
0 to 5
Stall prevention operation reduction
-
66
0 to 400Hz
starting frequency
67
Number of retries at fault occurrence
0 to 10, 101 to 110
68
Retry waiting time
0.1 to 360s
69
Retry count display erase
0
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
0.01Hz
9999
216
0.01Hz
9999
216
0.01Hz
9999
216
0.01Hz
9999
216
1
0
238
1
0
331
0.01Hz
9999
233
0.01Hz
9999
233
0.01Hz
9999
233
0.01Hz
9999
233
0.01Hz
9999
233
0.01Hz
9999
233
0.001
0
343
1
0
389
0.1%
10%
70
0.01Hz
6Hz
70
0.01Hz
9999
70
0.1/0.01s
5/10/15s
234
*2
0.1/0.01s
9999
234
0.1%
9999
244
0.01Hz
9999
244
0.1%
9999
335, 396
0.01A
9999
379
1
0
345
1
1
345
0.01Hz
60Hz
352
Rated inverter
0.01A
352
current
0.1s
9999
367
0.1s
1s
367
1
0
226
1
0
250
0.01A
9999
241
1%
9999
241
1%
9999
241
1
0
376
0.01Hz
60Hz
335
1
0
376
0.1s
1s
376
1
0
376
170
Control Mode-based Correspondence
Instruction Code
[Pr.]
Option
V/F control
24
18
98
0
25
19
99
0
26
1A
9A
0
27
1B
9B
0
29
1D
9D
0
30
1E
9E
0
31
1F
9F
0
32
20
A0
0
33
21
A1
0
34
22
A2
0
35
23
A3
0
36
24
A4
0
37
25
A5
0
40
28
A8
0
41
29
A9
0
42
2A
AA
0
43
2B
AB
0
44
2C
AC
0
45
2D
AD
0
46
2E
AE
0
47
2F
AF
0
48
30
B0
0
51
33
B3
0
52
34
B4
0
54
36
B6
0
55
37
B7
0
56
38
B8
0
57
39
B9
0
58
3A
BA
0
59
3B
BB
0
60
3C
BC
0
61
3D
BD
0
62
3E
BE
0
63
3F
BF
0
65
41
C1
0
66
42
C2
0
67
43
C3
0
68
44
C4
0
69
45
C5
0
170
PARAMETER
Table
General-
Advanced
purpose
magnetic
magnetic-
flux vector
flux vector
control
control
×
×
×
×
×
×
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents