[Pr.]
Name
Setting Range
261
Power failure stop selection
0, 1, 2
-
267
Terminal 4 input selection
0, 1, 2
-
268
Monitor decimal digits selection
0, 1, 9999
-
269
Parameter for manufacturer setting. Do not set.
-
295
Magnitude of frequency change setting
0, 0.01, 0.10, 1.00, 10.00
296
Password lock level
1 to 6, 101 to 106, 9999
297
Password lock/unlock
1000 to 9999(0 to 5, 9999)
-
298
Frequency search gain
0 to 32767, 9999
Rotation direction detection selection at
-
299
0, 1, 9999
restarting
Communication operation command
338
0, 1
source
339
Communication speed command source
0, 1, 2
340
Communication startup mode selection
0, 1, 10
342
Communication EEPROM write selection
0, 1
343
Communication error count
-
450
Second applied motor
0, 1, 9999
495
Remote output selection
0, 1, 10, 11
496
Remote output data 1
0 to 4095
Stop mode selection at communication
-
502
0, 1, 2
error
503
Maintenance timer
0(1 to 9998)
504
Maintenance timer alarm output set time
0 to 9998, 9999
549
Protocol selection
0, 1
PU mode operation command source
551
2, 4, 9999
selection
555
Current average time
0.1 to 1s
556
Data output mask time
0 to 20s
Current average value monitor signal
557
0 to 500A
output reference current
-
561
PTC thermistor protection level
0.5 to 30kΩ, 9999
-
563
Energization time carrying-over times
(0 to 65535)
-
564
Operating time carrying-over times
(0 to 65535)
-
571
Holding time at a start
0 to 10s, 9999
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
1
0
1
0
1
9999
0.01
0
1
9999
1
9999
1
9999
1
0
1
0
1
0
1
0
1
0
1
0
1
9999
1
0
1
0
1
0
1
0
1
9999
1
0
441, 459
1
9999
0.1s
1s
0.1s
0s
Rated inverter
0.01A
current
0.01kΩ
9999
1
0
1
0
0.1s
9999
196
Instruction Code
[Pr.]
373
261
45
217
267
4B
345
268
4C
269
Parameter for manufacturer setting. Do not set.
389
295
67
387
296
68
387
297
69
367
298
6A
367
299
6B
436
338
26
436
339
27
434
340
28
443
342
2A
459
343
2B
266
450
32
77
495
5F
77
496
60
-
502
02
74
503
03
74
504
04
549
31
436
551
33
75
555
37
75
556
38
75
557
39
50
561
3D
345
563
3F
345
564
40
232
571
47
Control Mode-based
Correspondence Table
General-purpose
V/F control
magnetic-flux
vector control
C5
2
CB
2
CC
2
E7
2
E8
2
E9
2
EA
2
EB
2
A6
3
A7
3
A8
3
AA
3
AB
3
B2
4
DF
4
E0
4
82
5
83
5
84
5
B1
5
B3
5
B7
5
B8
5
B9
5
BD
5
BF
5
C0
5
C7
5
196
PARAMETER
×
×
×
×
*6
*6
*6
*6
*6
*6
2
×
×
×
×
×
×
×
×
×
×
*6
*6
*6