Components (Rear); Figure 2.12 Controller (Fc Model) - Fujitsu Eternus DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Chapter 2 Components
2.1 Controller Enclosure
2.1.4

Components (Rear)

This section describes the controllers and the power supply units in the rear of the controller
enclosure.
2.1.4.1
Controllers
The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile mem-
ory, host interface adapters, drive interface (DI) ports, and LAN ports.
The controller controls all operations in the ETERNUS DX Disk storage system.
FC model

Figure 2.12 Controller (FC model)

Part explanation
LAN (RMT) port, LAN (MNT) port
These are the RJ-45 connectors to connect LAN cables. LAN (RMT) port is not used in the
EMEA&I region.
A single controller has one LAN (RMT) port and one LAN (MNT) port.
FC port (0 (left), 1 (right))
These are the Dual LC connectors to connect FC cables.
PWC port
This port is used for power synchronization.
DI (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a miniSAS cable.
LEDs
The states of LEDs are listed below.
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Installation-
SCU STATUS LED
IDENTIFY LED
DI (OUT) LINKUP LED
LAN (RMT) port
LAN (MNT) port
ACT LED
LINK LED
DI (OUT) port
33
Copyright 2014 FUJITSU LIMITED
FC LINKUP/FAULT LED
FC port (0 (Left), 1 (Right))
UNIT READY/FAULT LED
MASTER LED
PWC port
P3AM-5502-05ENZ0

Advertisement

Table of Contents
loading

Table of Contents