Trunk Disconnect Detection Timer

Software Version CPC-S and CPC-M, Version 1 0 and higher
Address FF2 (Trunk)# 18# (0-15)#
Description
When the trunk side of a CO call disconnects, the CO sends the DBS 824 a
disconnect signal by opening the loop (cutting voltage) for a specified length
of time
This timer determines how long the DBS 824 expects the disconnect signal to
last. If set to default, an open loop of 350 ms or more will be interpreted as a
disconnect signal
The standard range for CO disconnect signals is 350 to 600 ms
Programming
Table 2-2
Trunk disconnect detection timer
issued 3/l /95
FF2 (l-6 or l-8)# 18# (0115)#
Trunk Number
CPC-S l-6
CPC-M l-8
Address
Number
Ignore disconnect
0
Over 50 ms
1
I Over 100 ms
2
3
4
Over 200
Over 250 ms
5
6
Over 300
I Over 350 ms
Over 700 ms
14
15
Over 750 ms