Voice Announce Unit (VAU)

Voice Announce Unit (VAU)
Guidelines
l
l
l
l
Ins talla tio n
1
2
Table 5 5
Switch settings for SWI, VAU
5-24
Operating temperatures for the Voice Announce Unit (VB-43708) should
be between 35 and 105' F
Maximum loop resistance for the VAU is 10 Ohms
The VAU contains a rechargeable lead-acid battery Recharging circuity
for the battery is included on the VAU
The ports used for the VAU must have all FF key assignments cleared
before voice messages and abbreviated dial numbers are programmed
Remove the cover from the Voice Announce Unit
Set SW 1 and SW2 according to the following tables (Default settings are
italicized )
See Figure 5-22 for the location of the DIP switches
Switch
1
OFF=Disable blind transfer
(VAU chip 1 1 or later is required for blind transfer )
2
ON=Small DBS
OFF=DBS I DBS 824
3
OFF=One message up to 32 seconds
DBS 824-l O-300
Telephones and Peripheral Equipment
Function
Issued 3/l /95