Operator Access - Panasonic DBS 824 Manual

Hide thumbs Also See for DBS 824:
Table of Contents

Advertisement

Operator Access

Operator Access
Software Version CPC-S and CPC-M, Version 1 0 and higher
Address
Description
This Operator Access switch works only if the system is programmed to use
the new NANP dialing plan (FF7 l# 16# l#) Also, this switch applies only
to TRS types 2-6 (TRS types 0 and 1 do not allow outbound dialing, TRS
type 7 allows all dialing)
Use this address to block extension(s) from being able to access a trunk and
dialing "O", "OO", "1OXXXO" or "1OlXXXXO" to reach an operator This
would prevent a user from being able to circumvent a TRS restriction by
asking the operator to place a long-distance call
If this switch is set to "Restrict" (default) and an extension user accesses a
trunk and dials the operator, the system will wait 6 seconds before
automatically disconnecting the call, if the user dials additional digits within
6 seconds, the system will check other switches (if programmed) to allow or
restrict the call, such as "International Calling On Extensions" (FF7 l# lS#),
"7-Digit Toll Restriction" (FF7 l# ll-15#), etc
Programming
I
Related Programming
Dialing Plan Switch
Equal Access Code Format FF7 l# 20# (0 or l)#
7-12
FF7 l# 17# (1-16
Extension Port
CPC-S 1-16
CPC-M, l-24
FF7 l# 16# (0 or l)#
DBS 824-l O-400
or
or
O=Restrict operator calls
FF7
I
Issued 3/l /95

Advertisement

Table of Contents
loading