Chapter 3 Setup
Item name
Alert (*3)
Computer Name (*4)(*5)
Community Name (*4)
Alert Acknowledge (*4)(*6)
Alert Process (*4)
Retry Count (*4)
Timeout (sec) (*4)
Alert Receiver 1 (*4)(*7)
IP Address
Alert Receiver 2 (*4)(*7)
IP Address
Alert Receiver 3 (*4)(*7)
IP Address
Alert Level (*4)
Alert Level
(*1) Addresses and character strings are example.
(*2) Factory-set value.
(*3) Displayed when [Configuration] → [Miscellaneous] → "PEF(Platform Event Filtering)" is set to "Enable".
(*4) Displayed when Alert is set to "Enable".
(*5) Computer name must be specified with 1-byte alphanumeric.
(*6) Set to "Enable" when NEC ESMPRO Manager is used for management.
(*7) At least one destination must be enabled.
(*8) When the [Alert Test] button is pressed, a pseudo event to the specified destination.
(*9) You can set an alert level individually for each sensor type.
Setup value (*1)
Enable or disable SNMP alert.
Specify the host name used for SNMP alert.
Specify the community name used for
SNMP alert.
Select Enable or Disable to acknowledge
response from destination.
Specify the alert destination.
One Alert Receiver
All Alert Receiver
Specify the number of retries to send an
alert. Allowable range is between 0 and 7.
Specify the timeout time to send an alert.
Allowable range is between 3 and 30.
Specify the IP address of destination. (*8)
Specify the IP address of destination. (*8)
Specify the IP address of destination. (*8)
Specify the type of event to be sent.
Critical
Critical, Non-critical
Critical, Non-critical, Information
Separate Setting (*9)
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
7. Using Remote Management
Default value (*2)
Disable
Blank
public
Enable
One Alert Receiver
3
6
0.0.0.0
0.0.0.0
0.0.0.0
Critical, Non-critical