Chapter 3 Setup
Setting range and default value
Item
Power
PSU Redundancy
Maintenance
Maintenance Mode
Maintenance Account Password
Cooling
BBU on PCI Slot
Fault Handling
Failing Unit Removal
Degraded Server Boot Policy
FRB2 Monitoring
POST Monitoring
Description
Specify the redundancy of power
supply unit.
– 2N: Power supply system redundant
mode (2N redundancy)
– N+1: Power supply unit redundant
mode (N+1 redundancy)
– N: Non-redundant mode (N
configuration)
Select whether the maintenance
personnel can work with the system in
this mode, and specify the time allowed
for maintenance. Specify the allowed
time in unit of minute, in the range
between 6 and 1440).
While this mode is on, an icon is
displayed at upper right corner of
screen.
– Disable: Allowed time for
maintenance (default): 0 minute
– Enable: Allowed time for
maintenance (default): 6 minutes
Set password for maintenance user.
(*4)
Specify whether the battery backup unit
is installed on PCI card for external
SAS RAID. Change this parameter to
"Installed" when BBU is mounted. The
setting of power-saving mode of fan
control is also changed according to
this setting.
– Not-Installed
– Installed
Specify whether the failing component
is to be disconnected automatically.
– Disable
– Enable
Enable: Enables automatic removing of
the failing units.
Disable: Disables automatica removing
of the failing units.
Specify the boot policy for the
degraded server.
– Boot
– Not-Boot
Enable or disable the boot monitoring
feature (FRB2 phase) for the server
(hardware and BIOS). If Enabled, Hard
Reset is performed automatically when
bootup failed.
– Disable
– Enable
Enable or disable the boot monitoring
feature (POST phase) for the server
(hardware and BIOS).
If Enabled, Hard Reset is performed
automatically when bootup failed.
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
7. Using Remote Management
Default
When applied
value(*1)
At next boot
2N
Immediate
Disable
Immediate
Displayed by
[*].
At next boot
Not-Installed
At next boot
Enable
At next boot
Boot
Immediate
Enable
Immediate
Enable