NEC express5800 A2010b User Manual page 372

Hide thumbs Also See for express5800 A2010b:
Table of Contents

Advertisement

Chapter 3 Setup
Item
Boot Monitoring
OpROM Monitoring
Failure Flow Monitoring
Shutdown Monitoring
Diagnostics(*2)
Periodic Diagnosis(*2)
Configuration
Master Clock Module (*2)
Spare Memory Configuration
Mode (*2)
Spare PCIe Configuration Mode
(*1) Factory-set value.
(*2) Displayed only when selectable dependig on server model.
(*3) If changed from Disable to Enable, Monitoring time returns to the default value.
(*4) ASCII characters excluding [(space)], ["], [&], [?], [=], [\](backslash), and [#] can be accepted. Character
string must be in the range between 1 and 19 characters.
372
Description
– Disable
– Enable
Enable or disable the boot monitoring
feature of OS. If Enabled, Hard Reset
is performed automatically when
bootup failed.
– Disable
– Enable
Monitoring time: 1 to 60 minutes
Enable or disable the boot monitoring
feature (OpROM boot phase) for the
server (hardware and BIOS). If
Enabled, Hard Reset is performed
automatically when bootup failed.
– Disable
– Enable
Enable or disable the feature to monitor
fault processing performed at
occurrence of failure.
– Disable
– Enable
Monitoring time: 1 to 60 minutes
Enable or disable monitoring feature of
server shutdown. When Enabled,
forcibly shuts down the server if normal
shutdown fails.
– Disable
– Enable
Monitoring time: 1 to 60 minutes
Enable or disable periodic diagnosis for
spare hardware component.
– Disable
– Enable
Specify whether the master clock is
assigned to Primary CLK (the youngest
number) or Secondary CLK.
– Clock1
– Clock2
Select Static or Dynamic for mode to
configure memory.
– Static
– Dynamic
Select Static or Dynamic for mode to
configure PCIe card. (*1)
– Static
– Dynamic
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
7. Using Remote Management
Default
When applied
value(*1)
Immediate
Disable
Immediate
1 (*3)
Immediate
Disable
Immediate
Disable
Immediate
30 (*3)
Immediate
Enable
Immediate
10 (*3)
Immediate
Enable
At DC OFF:
Clock1
Immediate
Other than DC
OFF: At next boot
At next boot
Static
At next boot
Static