ACS550 User's Manual
Code Description
0305 FAULT WORD 1
Read-only copy of the Fault Word 1.
• When a fault is active, the
corresponding bit for the active fault is
set in the Fault Words.
• Each fault has a dedicated bit
allocated within Fault Words.
• See section
Fault listing
for a description of the faults.
• The control panel displays the word in
hex. For example, all zeros and a 1 in
Bit 0 displays as 0001. All zeros and a
1 in Bit 15 displays as 8000.
0306 FAULT WORD 2
Read-only copy of the Fault Word 2.
• See parameter 0305.
0307 FAULT WORD 3
Read-only copy of the Fault Word 3.
• See parameter 0305.
0308 ALARM WORD 1
• When an alarm is active, the
corresponding bit for the active alarm
is set in the Alarm Words.
• Each alarm has a dedicated bit
allocated within Alarm Words.
• Bits remain set until the whole alarm
word is reset. (Reset by writing zero to
the word.)
• The control panel displays the word in
hex. For example, all zeros and a 1 in
Bit 0 displays as 0001. All zeros and a
1 in Bit 15 displays as 8000.
0309 ALARM WORD 2
See parameter 0308.
Bit # 0305,
0
OVERCURRENT
1
DC OVERVOLT
2
DEV OVERTEMP
3
SHORT CIRC
on page
244
4
Reserved
5
DC UNDERVOLT
6
AI1 LOSS
7
AI2 LOSS
8
MOT OVERTEMP
9
PANEL LOSS
10
ID RUN FAIL
11
MOTOR STALL
12
CB OVERTEMP
13
EXT FAULT 1
14
EXT FAULT 2
15
EARTH FAULT
Bit #
0
OVERCURRENT
1
OVERVOLTAGE
2
UNDERVOLTAGE
3
DIRLOCK
4
COMM LOSS
5
AI1 LOSS
6
AI2 LOSS
7
PANEL LOSS
8
DEVICE OVERTEMP
9
MOTOR TEMP
10
Reserved
11
MOTOR STALL
12
AUTORESET
13
PFC AUTOCHANGE
14
PFC ILOCK
15
Reserved
1 0306,
FAULT WORD
FAULT WORD
Obsolete
THERM FAIL
OPEX LINK
OPEX PWR
CURR MEAS
SUPPLY PHASE
ENCODER ERR
OVERSPEED
Reserved
DRIVE ID
CONFIG FILE
SERIAL 1 ERR
EFB CON FILE
FORCE TRIP
MOTOR PHASE
OUTP WIRING
0308,
1
ALARM WORD
2 0307,
FAULT WORD
EFB 1
EFB 2
EFB 3
INCOMPATIBLE SW
USER LOAD CURVE
Reserved
Reserved
Reserved
Reserved
Reserved
System error
System error
System error
System error
System error
Param. setting fault
0309,
2
ALARM WORD
OFF BUTTON
PID SLEEP
ID RUN
Reserved
START ENABLE 1
START ENABLE 2
EMERGENCY STOP
ENCODER ERROR
FIRST START
Reserved
USER LOAD CURVE
START DELAY
Reserved
Reserved
Reserved
Reserved