32
Check that the starting of the motor does not cause any danger.
De-couple the driven machine if:
• there is a risk of damage in case of incorrect direction of rotation, or
• an ID Run needs to be performed during the drive start-up. ID Run is essential only in
applications that require the ultimate in motor control accuracy.
Apply input power.
The Basic Control Panel powers up into the Output mode.
The Assistant Control Panel asks if you want to run the Start-
up Assistant. If you press
run, and you can continue with manual start-up in a similar
manner as described below for the Basic Control Panel.

MANUAL ENTRY OF START-UP DATA

If you have an Assistant Control Panel, select the language
(the Basic Control Panel does not support languages). See
parameter
9901
alternatives. You find parameter descriptions in section
Complete parameter descriptions
The general parameter setting procedure is described below for the Basic
Control Panel. You find more detailed instructions for the Basic Control Panel
on page 67. Instructions for the Assistant Control Panel are on page 49.
The general parameter setting procedure:
1. To go to the Main menu, press
otherwise press
keys
2. Press
3. Find the appropriate parameter group with
.
4. Find the appropriate parameter in the group with
5. Press and hold
shown with
SET
6. Change the value with keys
you keep the key pressed down.
7. Save the parameter value by pressing
Start-up, control with I/O and ID Run

POWER-UP

EXIT
, the Start-up Assistant is not
for the values of the available language
starting on page 98.
if the bottom line shows OUTPUT;
repeatedly until you see MENU at the bottom.
/
until you see "PAr" and press
keys
for about two seconds until the parameter value is
under the value.
/
. The value changes faster while
(Group 99: START-UP
.
/
and press
keys
/
.
.
ACS550 User's Manual
00
REM
.
OUTPUT
FWD
CHOICE
REM
Do you want to
use the start-up
assistant?
Yes
No
EXIT
00:00
OK
DATA)
PAR EDIT
REM
9901 LANGUAGE
ENGLISH
[0]
CANCEL
00:00
SAVE
rEF
REM
MENU
FWD
-01-
REM
PAR
FWD
2001
REM
PAR
FWD
2002
REM
PAR
FWD
1500
REM
PAR
SET
FWD
1600
REM
PAR
SET
FWD
2002
REM
PAR
FWD
Hz
rpm
rpm

Hide quick links: