ACS550 User's Manual
Group 98: OPTIONS
This group configures for options, in particular, enabling serial communication with
the drive.
Code Description
9802
COMM PROT SEL
Selects the communication protocol.
0 =
– No communication protocol selected.
NOT SEL
1 =
– The drive communicates with Modbus via the RS485 channel (X1-communications, terminal).
STD MODBUS
• See also
Group 53: EFB
4 =
– The drive communicates via a fieldbus adapter module in option slot 2 of the drive.
EXT FBA
• See also
Group 51: EXT COMM
PROTOCOL.
MODULE.